Customer Service
+8618666881028

ESD Cleanroom & Test

Request a quote
Category
Card- free Static Access Control System

Card- free Static Access Control System

Features:

1.The three-roller gate static access control system is made according to ISO / CD8782-I standard, using touch test button (easy to operate, test fast), which is a stable and mature product.

2.the result of resistance test is whether qualified or not could be indicated by voice and light dual tips.

3. Could adjust resistance limits of the shoes and wrist strap and could also set the test time 

4. Support offline work, can be individually controlled channel gate, electric lock, air shower series equipment.

5. Integrated stainless-steel welding process, beautiful, wear-resistant, anti-rust, and waterproof.

6.Easy for installation and maintenance.


0.00
0.00
  
Product Description

Features:

1.The three-roller gate static access control system is made according to ISO / CD8782-I standard, using touch test button (easy to operate, test fast), which is a stable and mature product.

2.the result of resistance test is whether qualified or not could be indicated by voice and light dual tips.

3. Could adjust resistance limits of the shoes and wrist strap and could also set the test time 

4. Support offline work, can be individually controlled channel gate, electric lock, air shower series equipment.

5. Integrated stainless-steel welding process, beautiful, wear-resistant, anti-rust, and waterproof.

6.Easy for installation and maintenance.



Specification

Size:1200L*300W*1000Hmm

Channel Width520mm

Weightabout 45kg

Working environmentHumidity 5%90%/ Temperature-20°C85°C

Input VoltageAC220v50HZ

Lifetime8million times

Access time limits5 secs

Access speedabout 25person/min

Access mode: Test resistance when enter, infrared sensor control when out

Test mode:   1. Test wrist strap only and open the gate

2.Test feet only and open the gate

3.Test wrist Strap and feet simultaneously and open the gate

(Note: Could only choose one mode at the same time)

Test range : Hand 750KΩ---20MΩ     feet:750KΩ---100MΩ(the default value can be customized

                               
Testing steps:

1, Test shoes: standing on the pedal press the test button, if pass, the gate would open

2, Test shoes and wrist strap: plug in the static wrist strap, stand on the pedal, if pass, the gate would open.

After the test, there will be indication of the arrow light and sound prompts. Go out and press the open button to go out.

Precautions:

Employees must wear qualified anti-static shoes when entering the workshop, prohibit the bare feet and wearing conductive shoes, and prohibit wearing non-anti-static shoes such as normal shoes

If multiple tests failed, please check the shoes cleanliness, should pay attention to keep the shoes clean. If multiple tests are failure, need to replace the anti-static shoes

                                 

Installation

1. Place the machine where you want to install and mark the four holes on the bottom of the machine

2. Use drill No. 12 to punch the marker position and fasten the machine with expansion bolt # 10.

3. Insert the pedal wire into the machine, connect the left foot red wire to the fourth pin of the circuit board 5P terminal, and the right blue wire to the fifth pin.

4. Connect the 220V power to air switch in the control box, it can be used.