ESD Cleanroom & Test
Features:
1.The three-roller gate static access control system is made according to ISO / CD8782-I standard, using touch test button (easy to operate, test fast), which is a stable and mature product.
2.the result of resistance test is whether qualified or not could be indicated by voice and light dual tips.
3. Could adjust resistance limits of the shoes and wrist strap and could also set the test time
4. Support offline work, can be individually controlled channel gate, electric lock, air shower series equipment.
5. Integrated stainless-steel welding process, beautiful, wear-resistant, anti-rust, and waterproof.
6.Easy for installation and maintenance.
Features:
1.The three-roller gate static access control system is made according to ISO / CD8782-I standard, using touch test button (easy to operate, test fast), which is a stable and mature product.
2.the result of resistance test is whether qualified or not could be indicated by voice and light dual tips.
3. Could adjust resistance limits of the shoes and wrist strap and could also set the test time
4. Support offline work, can be individually controlled channel gate, electric lock, air shower series equipment.
5. Integrated stainless-steel welding process, beautiful, wear-resistant, anti-rust, and waterproof.
6.Easy for installation and maintenance.
Specification
Size:1200L*300W*1000H(mm)
Channel Width:520(mm)
Weight:about 45kg
Working environment:Humidity 5%…90%/ Temperature-20°C…85°C
Input Voltage:AC220v,50HZ
Lifetime:8million times
Access time limits:5 secs
Access speed:about 25person/min
Access mode: Test resistance when enter, infrared sensor control when out
Test mode: 1. Test wrist strap only and open the gate
2.Test feet only and open the gate
3.Test wrist Strap and feet simultaneously and open the gate
(Note: Could only choose one mode at the same time)
Test range : Hand 750KΩ---20MΩ feet:750KΩ---100MΩ(the default value can be customized )
Testing
steps:
1, Test shoes: standing on the pedal press the test button, if pass, the gate would open
2, Test shoes and wrist strap: plug in the static wrist strap, stand on the pedal, if pass, the gate would open.
After the test, there will be indication of the arrow light and sound prompts. Go out and press the open button to go out.
Precautions:
Employees must wear qualified anti-static shoes when entering the workshop, prohibit the bare feet and wearing conductive shoes, and prohibit wearing non-anti-static shoes such as normal shoes
If multiple tests failed, please check the shoes cleanliness, should pay attention to keep the shoes clean. If multiple tests are failure, need to replace the anti-static shoes
Installation
1. Place the machine where you want to install and mark the four holes on the bottom of the machine
2. Use drill No. 12 to punch the marker position and fasten the machine with expansion bolt # 10.
3. Insert the pedal wire into the machine, connect the left foot red wire to the fourth pin of the circuit board 5P terminal, and the right blue wire to the fifth pin.
4. Connect the 220V power to air switch in the control box, it can be used.
Add: No.151 Houjie Road, Houjie
Town, Dongguan, Guangdong, China
Tel: +86 18666881028 WhatsApp:+86 18666881028
Inquiry Mail: wangdep@esd-conductive.com